WMC-RC-PM8000D 15″ Multi-parameter Patient Monitor
Category: Patient Monitors
-
Features:
Alarm review: 200 alarm events
Easy operation/stable performance
Electrotome/defibrillation tolerance
Light & handy
Measurement: ECG/ SpO2/NIBP/HR&PR/Resp
Network: Wire/wireless network & online update
NIBP review: 10000 events
Power Supply: AC & DC Data Storage
Restore within 5 seconds after defibrillation
Support drug concentration titration analysis
Trend diagram/table: 720h
Triplex alarms: Light/Sound (High/medium/low levels adjustable) Electrode Disconnection Alarm (Diagram)
Wave review: 12h
Windows XP Operating System
Support drug concentration titration analysis.
Product Application
- Application: Adult/Pediatric/Neonatal/Medicine/Surgery/ Operating Room/ICU/CCU
Physical Specification
Product dimension & weight Equipment: 370mm×160mm×350mm&4.5kg
Package: 420mm×380 mm×285mm&6.6kg
Monitor
15” real color TFT screen, Resolution:1024*768
Battery
Electrical Power
11.1V 24wh Li-ion battery
AC: 100 ~ 240V, 50Hz/60Hz
2h operating after full charge(one piece)
DC: Built-in rechargeable battery
5min operating after low battery alarm
Product Technique Specification
ECG
3Leads: RA, LA, LL Lead mode: I, II, III 5 Leads: RA, LA, LL, RL, V Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V |
Resp
Method: impedance between RA-LL Resp Impedance range: 0.3 ~ 3Ω Base Impedance range: 200Ω ~ 4000Ω Bandwidth: 0.3 ~ 2.5Hz |
Battery
11.1V 24wh Li-ion battery
2h operating after full charge(one piece) 5min operating after low battery alarm AC and Drift tolerance |
SegmentRange:
-2.0mV ~ +2.0mV (accuracy 0.02mV) Heart/Pulse Rate Measure range: Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm Accuracy: ±1% Resolution: 1 bpm
NIBP Method: Oscillometry Measure mode: Manual, Auto, STAT Measure Heart/Pulse Rate Measure range:Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm Accuracy: ±1% Resolution: 1 bpm Optional: Temp Channel 2
Measure & alarm range 0 ~ 50°C Resolution 0.1°C
Accuracy (no sensor) ± 0.1°C (0~50°C |
SupportheartPace–makingAnalysis
13 Arrhythmia Analysis: Asystole, V-Fibrillation/Tachycardia, Single/Paired/Multiform PVC, Bigeminy, Trigeminy, Polycardia, P-0N-T, Bradycardia, Leaky-wave, Pacemaker not captured, Pacemaker failure |
|
SpO2
Measurement range: 0 ~ 100% Resolution: 1% Accuracy: 70% ~ 100% ±2% 40% ~ 69% ±3% |
System Inputs & Outputs
NIBP/SpO2/Temp/ECG/IBP Sensor Sockets RJ45 port
Product Standard Package
Main unit
- (15”screen) NIBP
- NIBP cuff & tube
- ECG cable
- SpO2 sensor
- Temperature probe
- Lithium-ion battery
- Optional Accessories: Touch screen, Trolley bracket, Hanging bracket, Monitor recorder, Vehicle-mounted power supply