WMC-RC-E10 Modular Patient Monitor
Full touch screen selectable, more conveninet for operation.
Technical Specification
Quality Standards and Classification
CE, ISO13485 SFDA: Class Ⅱb Anti-electroshock degree: ClassⅠequipment (internal power supply) TEMP/SpO 2 /NIBP: BF ECG/Resp: CF Application Range Adult/ Pediatric /Neonatal/ Medicine/ Surgery/ Operating Room/ ICU/ CCU Display 10”, 12.1”,15”real color TFT touch screen Environment Operating environment : Temperature: 0 ~ 40 ℃ Humidity: ≤85% Altitude: -500 ~ 4600m Transport and Storage environment : Temperature: -20 ~ 60 ℃ Humidity: ≤93% Altitude: -500 ~ 13100m Power Requirements AC: 100 ~ 240V, 50Hz/60Hz DC: Built-in rechargeable battery Battery: 4000mA 11.1V lithium battery 2h operating after full charge(one piece) 5min operating after low battery alarm Dimension and weight Equipment: E10: 271 mm × 158 mm ×286 mm; 3.31 kg E10: 380 mm ×350 mm × 300 mm; 5.6 kg Date Storage Trend diagram/table: 7x24h NIBP review: 400 events Wave review: 100min Alarm review: 100 alarm events Support drug concentration titration analysis ECG 5 Leads: RA, LA, LL, RL, V Lead mode:Ⅰ,Ⅱ, Ⅲ, aVR, aVL, aVF, V Increase: ×250,×500,×1000,×2000 Sensitivity: > 200 uV (Peak-to-peak value) Input impedance: > 5 ( megohm ) Bandwidth: Surgery:1 ~ 20 Hz Monitor: 0.5 ~ 40 Hz Diagnostic: 0.05 ~ 130 Hz CMRR: ≥ 100dB Polarization Voltage: ± 300mV Baseline Recovering Time: After defibrillation< 3 seconds Signal Range: 8 mV(Peak-to-peak value) Calibrating Signal: 1mV, precision ±5% ST Segment ST Segment Range: -2.0mV ~ +2.0mV Accuracy: 0.02mV RESP Method: RA-LL impedance Resp Impedance range: 0.3 ~ 3 Ω Base Impedance range: 200 Ω ~ 4000 Ω Bandwidth: 0.1 ~ 2.5Hz Resp rate: Adult: 0 ~ 120BrPM Neonatal/Pediatric: 0 ~ 150BrPM Resolution: 1BrPM Precision:±2 BrPM Asphyxia Alarm: 10~40 seconds |
NIBP
Method: Pulse wave oscillometry Work mode: Manual/ Auto/ STAT Measure interval of auto mode: 1,2,3,4,5,10,15,30,60,90,120,180,240,480 minute(s) Measuring Time of STAT Mode: 5 minutes PR range: 40 ~ 240bpm Measure & alarm range: Adult: SYS 40 ~ 270mmHg DIA 10 ~ 215mmHg MEAN 20 ~ 235mmHg Pediatric: SYS 40 ~ 200mmHg DIA 10 ~ 150mmHg MEAN 20 ~ 165mmHg Neonatal: SYS 40 ~ 135mmHg DIA 10 ~ 100mmHg MEAN 20 ~ 110mmHg Static pressure range: 0 ~ 300mmHg Precision:± 3mmHg Pressure precision: Max. average error:±5mmHg Max. standard deviation:±8mmHg Overvoltage protection: Adult: 300mmHg Pediatric: 240mmHg Neonatal: 150mmHg SpO2 Range: 0 ~ 100% Resolution: 1% Precision: 70% ~ 100%: ±2 DIGIT 0% ~ 69%: ±no definition given Pulse Rate Range: 20 ~ 300bpm Resolution: 1bpm Precision: ±3bpm TEMP Channel: 2 Measure & alarm range: 0 ~ 50 ℃ Resolution: 0.1 ℃ Precision (no sensor):±0.1 ℃ Standard Accessories 1. NIBP cuff & tube 2. ECG cable & electrodes 3. SpO2 sensor 4. TEMP probe 5. Lithium-ion battery 6. Power cable 7. Operator’s manual Optional 1. CO2 module 2. IBP module 3. Trolley bracket 4. Hanging bracket 5. Monitor recorder IBP Label ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measuring and alarm range ART: 0 ~ 300 mmHg PA: -6 ~ 120 mmHg CVP/RAP/LAP/ICP: -10 ~ 40 mmHg P1/P2: -10 ~ 300 mmHg Press Sensor Sensitivity: 5 uV/V/mmHg Impedance: 300-3000Ω Resolution: 1 mmHg Accuracy: ±2% or ±1mmHg, which great Actualization interval: about 1 Sec. CO2 Side/Main stream Measurement Infrared radiation absorption technique measurement range: 0 ~ 99mmHg Precision: 0 ~ 40mmHg ±2mmHg 41 ~76mmHg ±5mmHg 77~99mmHg ±10mmHg Resolution: 1mmHg Pumping rate: 70ml/min, 100ml/min Accuracy: 15% or 15ml/min big AwRR measuring range: 0 ~120BrPM Precision: 0 ~70BrPM: ±2BrPM >70BrPM: ±5BrPM |